Ecological Archives E088-009-A1

Roland Jansson, Hjalmar Laudon, Eva Johansson, and Clemens Augspurger. 2007. The importance of groundwater discharge for plant species number in riparian zones. Ecology 88:131–139.

Appendix A. Statistical tables showing the results of the analyses of covariance comparing the number of species and species density between sites with and without groundwater discharge in the free-flowing Vindel and regulated Ume rivers.

TABLE A1. Results of ANCOVA describing variation in number of plant species in 1-m to 50-m wide riparian transects in the Vindel and Ume Rivers. Location is a random factor, groundwater type (discharge or non-discharge) a fixed factor, and substrate fineness a covariate. Significant P values are boldfaced.

Source of variation

df

MS

F

P

         

1-m wide transects

 
 
 
 

   Location

19

260

5.96

<0.0001

   Groundwater type

1

2655

62.51

<0.0001

   Substrate fineness

1

5

0.12

0.74

   Groundwater × substrate fineness

1

529

12.45

0.003

   Error

17

53

 
 

5-m wide transects

 
 
 
 

   Location

19

296

5.13

<0.0001

   Groundwater type

1

2692

46.69

<0.0001

   Substrate fineness

1

3

0.05

0.82

   Groundwater × substrate fineness

1

441

7.64

0.013

   Error

17

58

 
 

25-m wide transects

 
 
 
 

   Location

19

320

4.11

0.003

   Groundwater type

1

3260

41.91

<0.0001

   Substrate fineness

1

7

0.10

0.76

   Groundwater × substrate fineness

1

469

6.03

0.025

   Error

17

78

 
 

50-m wide transects

 
 
 
 

   Location

19

297

4.08

0.003

   Groundwater type

1

3459

47.44

<0.0001

   Substrate fineness

1

28

0.38

0.54

   Groundwater × substrate fineness

1

503

6.90

0.018

   Error

17

73

 
 

 

TABLE A2. Results of ANCOVA describing variation in plant species density in 1-m to 50-m wide riparian transects in the Vindel and Ume Rivers. Location is a random factor, groundwater type (discharge or non-discharge) a fixed factor, and substrate fineness a covariate. Significant P values are boldfaced.

Source of variation

df

MS

F

P

         

1-m wide transects

 
 
 
 

   Location

19

820

0.57

0.88

   Groundwater type

1

3756

2.62

0.12

   Substrate fineness

1

30

0.02

0.89

   Groundwater × substrate fineness

1

1943

1.36

0.26

   Error

17

1435

 
 

5-m wide transects

 
 
 
 

   Location

19

92

0.55

0.90

   Groundwater type

1

3058

18.26

<0.001

   Substrate fineness

1

1

0.003

0.95

   Groundwater × substrate fineness

1

786

4.53

0.048

   Error

17

 
 
 

25-m wide transects

 
 
 
 

   Location

19

114

0.85

0.64

   Groundwater type

1

3525

26.09

<0.0001

   Substrate fineness

1

28

0.21

0.65

   Groundwater × substrate fineness

1

720

5.33

0.034

   Error

17

135

 
 

50-m wide transects

 
 
 
 

   Location

19

131

1.03

0.48

   Groundwater type

1

3733

29.46

<0.0001

   Substrate fineness

1

3

0.03

0.87

   Groundwater × substrate fineness

1

797

6.29

0.023

   Error

17

127

 
 


[Back to E088-009]